In this section: Explore

Explore · Printable resource · Printable

Water quality report column guide

A printable key to the tables in a yearly drinking water quality report, also called a Consumer Confidence Report (CCR). It explains each column, unit and abbreviation, then walks through a fictional sample table row by row.

This page is for printing or copying by hand. Nothing you write here is collected or stored.

A front door with a porch light and potted plant inside an arch, with a house key and a toolbox.

Who this is for

Anyone holding a water quality report and trying to make sense of its tables: renters, homeowners, caregivers, and people helping a relative or neighbor. It uses the terms found in U.S. reports, with California's extra columns labeled.

How to use it

  1. Open your report to the table of detected contaminants. Keep this guide beside it.
  2. Match each column heading in your report to Part 1. Headings vary a little from system to system.
  3. Read one row at a time, left to right. Compare numbers only within the same row, because each row uses its own units.
  4. Read the footnotes under the table. They often explain high results, sample dates or wells taken out of service.
  5. Write down what you find in Part 5, and take it with you if you call your water system or talk to a clinician.

Part 1: The columns you will see

Column heading (common versions)What it meansWhat to check
Contaminant, Parameter, ConstituentThe substance measured, with its units in parentheses.The units, for example mg/L or µg/L.
MCL, Primary standardMaximum Contaminant Level: the legal limit.Is the level found, and the top of the range, at or below it?
Secondary MCL, SMCLA limit for taste, odor or appearance, not health.High results can explain color, staining or taste.
MCLG, or PHG (MCLG) in CaliforniaThe health goal: EPA's MCLG, or California's Public Health Goal where one exists. Not enforceable.How far the level found sits above the goal, if at all.
MRDL / MRDLGLimit and goal for disinfectants such as chlorine.The level found should be at or below the MRDL.
AL, Action LevelFor lead and copper, the level that triggers extra steps.The 90th percentile column, not the highest single home.
TT, Treatment TechniqueA required treatment process instead of a numeric limit.Often used for turbidity (cloudiness), a check on filtration.
NL, Notification Level (California)A health-based advisory level for a chemical without an MCL.Going above it means the system must notify local officials; it is not an MCL violation.
Average, Level detected, Highest levelThe figure used to judge compliance, often an average across sources or over time.In a system with many wells, the average can hide high wells.
Range, Range of detectionsThe lowest and highest results.The top number, and whether a footnote explains it.
90th percentileFor lead and copper: roughly the result that 9 of 10 sampled homes were at or below.Compare with the AL.
Sites above ALNumber of sampled homes above the lead or copper action level.Any number above zero is worth asking about.
Sample date, Last sampledWhen the sample was taken. Some contaminants are sampled less than once a year.Older dates are allowed for some contaminants; the report must say so.
Violation (Yes/No)Whether the system broke a standard.If yes, read the explanation: how long, health effects, what was done.
Typical sourceWhere the contaminant usually comes from.Natural deposits, farming, industry, plumbing or treatment byproducts.

Part 2: Units

Written asMeansScale
mg/L or ppmmilligrams per liter, parts per million1 part per million is about 1 second in 11.5 days
µg/L, ug/L or ppbmicrograms per liter, parts per billion1,000 µg/L = 1 mg/L; 1 part per billion is about 1 second in nearly 32 years
ng/L or pptnanograms per liter, parts per trillion1,000 ng/L = 1 µg/L; 1 part per trillion is about 1 second in nearly 32,000 years
pCi/Lpicocuries per literradioactivity
NTUnephelometric turbidity unitscloudiness
µS/cm or µmho/cmmicrosiemens (or micromhos) per centimeterconductance, a rough sign of dissolved minerals
"as N"measured as nitrogennitrate's 10 mg/L limit is "as N"

Reports show each limit as a number of 1 or more, with the goal and the result in the same units. If a row looks odd, check the units first.

Part 3: Abbreviations

Short formStands for
NDNot detected at the reporting limit (not proof of zero)
N/ANot applicable
DLR (California)Detection limit for purposes of reporting
LRAALocational running annual average, used for disinfection byproducts
TTHM, HAA5Total trihalomethanes and five haloacetic acids, byproducts of chlorination
UCMRUnregulated Contaminant Monitoring Rule: federal sampling for chemicals that are not yet regulated
TCP1,2,3-trichloropropane
PFAS, PFOA, PFOSPer- and polyfluoroalkyl substances, a group of long-lasting industrial chemicals, and two of them

Part 4: A sample table, annotated

Example (fictional): This table and its numbers are invented for practice. They do not describe any real water system.

Contaminant (units)MCL [MRDL]PHG (MCLG) [MRDLG]AverageRangeViolationTypical source
Nitrate, as N (mg/L)10103.2ND–7.4NoFertilizer runoff; septic systems; natural deposits
Arsenic (µg/L)100.0042.1ND–6.0NoNatural deposits; orchard runoff
TTHM (µg/L)80N/A12 (highest LRAA)4–19NoByproduct of chlorination
Chlorine, as Cl2 (mg/L)[4.0][4]1.20.4–1.9NoDisinfectant added in treatment
Iron (µg/L), secondary300none40ND–120NoNatural deposits
Lead and copperALPHGHomes sampled90th percentileHomes above ALRange
Lead (µg/L)150.250ND0ND–8
Copper (mg/L)1.30.3500.210ND–0.35

How to read it:

  • Nitrate: The average and the top of the range are below 10, so there is no violation. Because the highest result, 7.4, is above 5, the report must also include a nitrate statement for people caring for infants. Parents using tap water for formula can ask a clinician what water to use.
  • Arsenic: Below the limit. The highest result, 6.0, is above 5, so an arsenic statement is required. The PHG of 0.004 is far lower than the limit, because the limit also weighs treatment cost.
  • TTHM: Judged by a running annual average at each sampling location, not single samples. The highest location average, 12, is well below 80.
  • Chlorine: The brackets mark a disinfectant limit and goal. Some chlorine is added on purpose to keep water safe in the pipes.
  • Iron: A secondary standard about color and taste, not health.
  • Lead: The 90th percentile is ND and no home was above 15, but one home measured 8. Lead comes mostly from service lines and home plumbing, so one home's tap can differ from the system's results. Starting November 1, 2027, the federal lead action level drops to 10.
  • Copper: Below the 1.3 action level at every sampled home.

Part 5: My report at a glance (fill in on paper)

ItemWhat my report says
Water system name and phone
Report year (data from)
Any violations listed?
Water sources (wells, river, lake, purchased water)
Contaminants with a result above half the MCL
Nitrate highest result
Arsenic highest result
Lead 90th percentile and homes above AL
How to see the service line inventory
Translation, large print or paper copy contact
Next public meeting on water

Part 6: Questions to ask your water system

  • Which wells or sources serve my address?
  • What do the footnotes on this row mean for my neighborhood?
  • What is my service line made of, and how was that decided?
  • Can you sample lead at my tap? Is there a cost?
  • Is a translated, large-print or paper copy available?
  • When will the next report or update come out?

Limitations

  • This guide explains report terms. It cannot tell you whether water is safe for a particular person. People who are pregnant, care for an infant or have a weakened immune system should ask a clinician about drinking water.
  • Reports summarize the previous year's sampling. They are not live data or alerts. Urgent problems must be announced separately within 24 hours.
  • Column names, units and layout vary by water system and state. When in doubt, call the number printed in your report.
  • Private wells and very small systems do not produce these reports. Owners need their own lab testing; in California, use a lab accredited by the State Water Board.
  • The sample table is fictional and for practice only.

Sources

  1. 40 CFR Part 141, Subpart O: Consumer Confidence Reports — U.S. Environmental Protection Agency regulation, Electronic Code of Federal Regulations, up to date as of October 20, 2026.
  2. 40 CFR Part 141, Subpart I: Control of Lead and Copper — Electronic Code of Federal Regulations, up to date as of October 20, 2026.
  3. 40 CFR 141.202, Tier 1 Public Notice — Electronic Code of Federal Regulations, up to date as of October 20, 2026.
  4. Consumer Confidence Report Reference Manual for Water Suppliers — California State Water Resources Control Board, Division of Drinking Water, updated January 2026.
  5. Public Health Goals (PHGs) — California Office of Environmental Health Hazard Assessment, accessed October 21, 2026.
  6. Drinking Water Notification Levels and Response Levels — California State Water Resources Control Board, last updated August 31, 2026.
  7. How to Read Drinking Water Quality Reports — Centers for Disease Control and Prevention, May 1, 2024.
  8. 2025 Annual Water Quality Report — City of Fresno Department of Public Utilities, June 2026 (used for typical column layout).
  9. Environmental Laboratory Accreditation Program — California State Water Resources Control Board, last updated August 20, 2026.