Who this is for
Anyone holding a water quality report and trying to make sense of its tables: renters, homeowners, caregivers, and people helping a relative or neighbor. It uses the terms found in U.S. reports, with California's extra columns labeled.
How to use it
- Open your report to the table of detected contaminants. Keep this guide beside it.
- Match each column heading in your report to Part 1. Headings vary a little from system to system.
- Read one row at a time, left to right. Compare numbers only within the same row, because each row uses its own units.
- Read the footnotes under the table. They often explain high results, sample dates or wells taken out of service.
- Write down what you find in Part 5, and take it with you if you call your water system or talk to a clinician.
Part 1: The columns you will see
| Column heading (common versions) | What it means | What to check |
|---|---|---|
| Contaminant, Parameter, Constituent | The substance measured, with its units in parentheses. | The units, for example mg/L or µg/L. |
| MCL, Primary standard | Maximum Contaminant Level: the legal limit. | Is the level found, and the top of the range, at or below it? |
| Secondary MCL, SMCL | A limit for taste, odor or appearance, not health. | High results can explain color, staining or taste. |
| MCLG, or PHG (MCLG) in California | The health goal: EPA's MCLG, or California's Public Health Goal where one exists. Not enforceable. | How far the level found sits above the goal, if at all. |
| MRDL / MRDLG | Limit and goal for disinfectants such as chlorine. | The level found should be at or below the MRDL. |
| AL, Action Level | For lead and copper, the level that triggers extra steps. | The 90th percentile column, not the highest single home. |
| TT, Treatment Technique | A required treatment process instead of a numeric limit. | Often used for turbidity (cloudiness), a check on filtration. |
| NL, Notification Level (California) | A health-based advisory level for a chemical without an MCL. | Going above it means the system must notify local officials; it is not an MCL violation. |
| Average, Level detected, Highest level | The figure used to judge compliance, often an average across sources or over time. | In a system with many wells, the average can hide high wells. |
| Range, Range of detections | The lowest and highest results. | The top number, and whether a footnote explains it. |
| 90th percentile | For lead and copper: roughly the result that 9 of 10 sampled homes were at or below. | Compare with the AL. |
| Sites above AL | Number of sampled homes above the lead or copper action level. | Any number above zero is worth asking about. |
| Sample date, Last sampled | When the sample was taken. Some contaminants are sampled less than once a year. | Older dates are allowed for some contaminants; the report must say so. |
| Violation (Yes/No) | Whether the system broke a standard. | If yes, read the explanation: how long, health effects, what was done. |
| Typical source | Where the contaminant usually comes from. | Natural deposits, farming, industry, plumbing or treatment byproducts. |
Part 2: Units
| Written as | Means | Scale |
|---|---|---|
| mg/L or ppm | milligrams per liter, parts per million | 1 part per million is about 1 second in 11.5 days |
| µg/L, ug/L or ppb | micrograms per liter, parts per billion | 1,000 µg/L = 1 mg/L; 1 part per billion is about 1 second in nearly 32 years |
| ng/L or ppt | nanograms per liter, parts per trillion | 1,000 ng/L = 1 µg/L; 1 part per trillion is about 1 second in nearly 32,000 years |
| pCi/L | picocuries per liter | radioactivity |
| NTU | nephelometric turbidity units | cloudiness |
| µS/cm or µmho/cm | microsiemens (or micromhos) per centimeter | conductance, a rough sign of dissolved minerals |
| "as N" | measured as nitrogen | nitrate's 10 mg/L limit is "as N" |
Reports show each limit as a number of 1 or more, with the goal and the result in the same units. If a row looks odd, check the units first.
Part 3: Abbreviations
| Short form | Stands for |
|---|---|
| ND | Not detected at the reporting limit (not proof of zero) |
| N/A | Not applicable |
| DLR (California) | Detection limit for purposes of reporting |
| LRAA | Locational running annual average, used for disinfection byproducts |
| TTHM, HAA5 | Total trihalomethanes and five haloacetic acids, byproducts of chlorination |
| UCMR | Unregulated Contaminant Monitoring Rule: federal sampling for chemicals that are not yet regulated |
| TCP | 1,2,3-trichloropropane |
| PFAS, PFOA, PFOS | Per- and polyfluoroalkyl substances, a group of long-lasting industrial chemicals, and two of them |
Part 4: A sample table, annotated
Example (fictional): This table and its numbers are invented for practice. They do not describe any real water system.
| Contaminant (units) | MCL [MRDL] | PHG (MCLG) [MRDLG] | Average | Range | Violation | Typical source |
|---|---|---|---|---|---|---|
| Nitrate, as N (mg/L) | 10 | 10 | 3.2 | ND–7.4 | No | Fertilizer runoff; septic systems; natural deposits |
| Arsenic (µg/L) | 10 | 0.004 | 2.1 | ND–6.0 | No | Natural deposits; orchard runoff |
| TTHM (µg/L) | 80 | N/A | 12 (highest LRAA) | 4–19 | No | Byproduct of chlorination |
| Chlorine, as Cl2 (mg/L) | [4.0] | [4] | 1.2 | 0.4–1.9 | No | Disinfectant added in treatment |
| Iron (µg/L), secondary | 300 | none | 40 | ND–120 | No | Natural deposits |
| Lead and copper | AL | PHG | Homes sampled | 90th percentile | Homes above AL | Range |
|---|---|---|---|---|---|---|
| Lead (µg/L) | 15 | 0.2 | 50 | ND | 0 | ND–8 |
| Copper (mg/L) | 1.3 | 0.3 | 50 | 0.21 | 0 | ND–0.35 |
How to read it:
- Nitrate: The average and the top of the range are below 10, so there is no violation. Because the highest result, 7.4, is above 5, the report must also include a nitrate statement for people caring for infants. Parents using tap water for formula can ask a clinician what water to use.
- Arsenic: Below the limit. The highest result, 6.0, is above 5, so an arsenic statement is required. The PHG of 0.004 is far lower than the limit, because the limit also weighs treatment cost.
- TTHM: Judged by a running annual average at each sampling location, not single samples. The highest location average, 12, is well below 80.
- Chlorine: The brackets mark a disinfectant limit and goal. Some chlorine is added on purpose to keep water safe in the pipes.
- Iron: A secondary standard about color and taste, not health.
- Lead: The 90th percentile is ND and no home was above 15, but one home measured 8. Lead comes mostly from service lines and home plumbing, so one home's tap can differ from the system's results. Starting November 1, 2027, the federal lead action level drops to 10.
- Copper: Below the 1.3 action level at every sampled home.
Part 5: My report at a glance (fill in on paper)
| Item | What my report says |
|---|---|
| Water system name and phone | |
| Report year (data from) | |
| Any violations listed? | |
| Water sources (wells, river, lake, purchased water) | |
| Contaminants with a result above half the MCL | |
| Nitrate highest result | |
| Arsenic highest result | |
| Lead 90th percentile and homes above AL | |
| How to see the service line inventory | |
| Translation, large print or paper copy contact | |
| Next public meeting on water |
Part 6: Questions to ask your water system
- Which wells or sources serve my address?
- What do the footnotes on this row mean for my neighborhood?
- What is my service line made of, and how was that decided?
- Can you sample lead at my tap? Is there a cost?
- Is a translated, large-print or paper copy available?
- When will the next report or update come out?
Limitations
- This guide explains report terms. It cannot tell you whether water is safe for a particular person. People who are pregnant, care for an infant or have a weakened immune system should ask a clinician about drinking water.
- Reports summarize the previous year's sampling. They are not live data or alerts. Urgent problems must be announced separately within 24 hours.
- Column names, units and layout vary by water system and state. When in doubt, call the number printed in your report.
- Private wells and very small systems do not produce these reports. Owners need their own lab testing; in California, use a lab accredited by the State Water Board.
- The sample table is fictional and for practice only.
Sources
- 40 CFR Part 141, Subpart O: Consumer Confidence Reports — U.S. Environmental Protection Agency regulation, Electronic Code of Federal Regulations, up to date as of October 20, 2026.
- 40 CFR Part 141, Subpart I: Control of Lead and Copper — Electronic Code of Federal Regulations, up to date as of October 20, 2026.
- 40 CFR 141.202, Tier 1 Public Notice — Electronic Code of Federal Regulations, up to date as of October 20, 2026.
- Consumer Confidence Report Reference Manual for Water Suppliers — California State Water Resources Control Board, Division of Drinking Water, updated January 2026.
- Public Health Goals (PHGs) — California Office of Environmental Health Hazard Assessment, accessed October 21, 2026.
- Drinking Water Notification Levels and Response Levels — California State Water Resources Control Board, last updated August 31, 2026.
- How to Read Drinking Water Quality Reports — Centers for Disease Control and Prevention, May 1, 2024.
- 2025 Annual Water Quality Report — City of Fresno Department of Public Utilities, June 2026 (used for typical column layout).
- Environmental Laboratory Accreditation Program — California State Water Resources Control Board, last updated August 20, 2026.
Printed from kpsgill.com. Check the page online for the latest version.